Customization: | Available |
---|---|
After-sales Service: | 12month Warranty,Lifelong Technical Service |
Function: | Inertial Sensors Testing |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Unit Under Test (UUT) | ||
Load weight | 40KG | |
Load height less than | ≤350mm | |
Load table size | ≥Φ520mm | |
Slip rings to UUT | Signal 140 ways, 3A @ 380VAC/50Hz, 45KW(Max) | |
Specifications | ||
Inner Axis | Outer Axis | |
Angular freedom | continuous | continuous |
Position | ||
Accuracy | ≤±3 arc sec | ≤±3 arc sec |
Resolution | 0.36 arc sec | 0.36 arc sec |
Repeatability | ≤±1 arc sec | ≤±1 arc sec |
Rate | ||
Range | ±0.001 deg/sec ~ ±1000 deg/sec | ±0.001 deg/sec ~ ±600 deg/sec |
Accuracy and stability | When θ<1 deg/sec | ≤1×10-3 (1 deg average) |
When 1 deg/sec<θ<10 deg/sec | ≤1×10-4 (10 deg average); | |
When θ≥10 deg/sec | ≤1×10-5 (360 deg average) | |
Dynamic | ||
Acceleration(with load) | 400 deg/sec2 | 100 deg/sec2 |
Mechanical | ||
Wobble | ≤±2 arc sec | ≤±2 arc sec |
Orthogonality | ≤±2 arc sec | ≤±2 arc sec |
Temperature Chamber (TC) | ||
Working volume | 600*600*500mm | |
Temperature range | -55ºC~+150ºC | |
Temperature stability | ≤±0.5ºC | |
Temperature change rate | not less than 5ºC/min, linear temperature change rate not less than 1ºC/min; | |
Temperature deviation: | ≤±2ºC | |
Temperature gradient: | ≤2ºC | |
Dimensions | ||
Machine platform dimensions | 2500*1005*2100mm | |
Total weight | 2300kg |