Table Parameters | |
---|---|
Table size | ∮500mm |
Table working height | See Figure 1 |
Table material | Stainless steel |
Rated load weight | 40kg |
Table flatness | ≤0.02mm |
Table end runout | ≤0.03mm |
Table magnetic leakage | <0.2mT |
Table mounting screw holes | M8, spacing 25mm (8 ray-shaped distribution), see Figure 2 for details |
Mechanical Platform Parameters | |
Axis tilt rotation error | ≤±2″ |
Angular position positioning accuracy | ≤±3″ |
Angular position positioning repeatability | ≤±2″ |
Angular range | 360° continuous rotation |
Angular position measurement resolution | 0.36″ |
Rate range | ±0.001°/s~±1000°/s |
Angular rate accuracy and rate stability | ω≤1°/s, 0.002 (1° average) 1°/s<ω<10°/s, 0.0002(10° average) ω≥10°/s, 0.00002 (360° average) |
Maximum angular acceleration | 300°/s² (rated load) |
Swing range | 0°~±45° |
Swing frequency | 0.02Hz~10Hz |
Equipment weight | ≤160kg |
User conductive slip ring | 1~32 rings, twisted pair shielded wire, rated current 2A 33~60 rings, single core shielded wire, rated current 3A |
Reliability Requirements | |
Continuous working time of the turntable | 48 hours |
Mean time between failures (MTBF) | 2000 hours |
Communication Method | |
Interface | RS232/RS422 |
Environmental Requirements | |
Power supply | Mechanical table: AC220V±10%, 50Hz, 2kW |
Operating ambient temperature | -10ºC~35ºC |
Storage ambient temperature | -20ºC~45ºC |
Relative humidity | ≤85%RH |
Other environmental conditions | Stable indoor airflow, no strong magnetic interference, no severe vibration and impact around |